Materials Needed
* Screwdriver
* Flashlight
* Multi-tester
Step 1 - Unplug Power
Be sure to first unplug the dryers electricity to avoid electrical shock, remove the access panel and set it to the side with the screws so they do not get lost during your inspection of the gas valve solenoid.
Step 2 - Adjustments
Select a high heat setting on the dial and then turn it on to observe the flame sensor. Watch as it changes in color. If it glows for several seconds then you will want to replace the gas valve solenoid. If the ignitor glows and stays lit for a longer time, then the problem is going to be found coming from your flame sensor. If it goes out quickly you will want to check your air intake nozzle.
Step 3 - Testing
Test the machines gas valve solenoid for electrical issues using a multi-tester. Simply set your multi-tester to the ohms setting of X10 and place a probe on each of the terminals. What you are looking for is a change from an infinity reading to roughly 1300 ohms. If the device shows different than 1300 ohms, the coil should be replaced.
http://www.prohometips.com/ This site facilitate with home improvement,home repair,extreme home makeover,home improvement site,HGTV,DIY,do-it-yourself,buying guides,consumer reports ,Free home improvement advice, great remodeling tips, and appliance buying guides by leading home improvement authority, DIY expert and HGTV personality
For furhter details about gas valve solenoid visit our website: http://www.prohometips.com/